W2 Series Zero Leakage Poppet Directional Valves – CETOP03/D03/NG6 manifold interface.
Available in 2/2, 3/2, 3/3, 4/3 and 4/4 configurations
Solenoid, air pilot or lever operation in most types. Manual over-ride as standard on solenoid operated versions.
Available with or without check valve or orifice disc in pressure port.
Special versions for accumulator and clamping systems with closed-crossover switching characteristics. Maximum flow rate 10l/min. Standard version W2N becomes W2P.
Coils can be replaced without disturbing or opening the hydraulic system.
Maximum pressure 315Bar.
Maximum flow 20 l/min (W2N types) or 10l/min (W2P types).
Fluid Temp. Range: -20°C, +70°C
Preferred voltages: 24V DC, 115V AC50-60Hz or 230V AC50-60Hz – others available on request.
Minimum pilot pressure of 5 bar is recommended for air operated valves.